Key findings

  • COP 0.8 at ultralow driving/regeneration temperature 62-64 C (both AC and refrigeration modes), across four isostructural metal variants.
  • Water uptake 0.31-0.34 g/g at 30 C, P/P0=0.3; heat of adsorption ~49 kJ/mol (easy regeneration).
  • Working capacity DeltaW 0.31-0.35 mL/mL (AC), 0.27-0.31 mL/mL (refrigeration) at Tdes=64 C.
  • Hydrothermal stability: full capacity after 1-month water soak, 5-day boiling water, 20 ad/desorption cycles.
  • Compares favorably vs SAPO-34 (0.29 g/g) and MIL-160/CAU-10/MOF-303.