Computational Analysis of Natural Ventilation Flows in Geodesic Dome Building in Hot Climates

Source: https://doi.org/10.3390/computation4030031

Overview

Peer-reviewed computational fluid dynamics study analyzing natural ventilation in geodesic dome buildings situated in hot climates. Airflow and temperature distributions and ventilation flow rates predicted using three-dimensional Reynolds-Averaged Navier-Stokes (RANS) equations.

The geodesic dome — a spherical form comprised of a complex network of triangles or polygonal facets — was developed by R. Buckminster Fuller in the late 1940s. Fuller’s design was based on the principle of “doing more with less,” discovering that if a spherical structure was created from triangles, it would have unparalleled strength.

Key Findings

Geometry Advantages

  • A 3v icosahedron dome offers “a smoother shape than a 2v and lower complexity than a 4v”
  • ~30% less surface area than a box house of equivalent volume → ~30% savings on cooling and heating bills
  • The concave interior creates natural airflow that allows hot or cool air to flow evenly throughout the dome
  • The spherical structure is one of the most efficient interior atmospheres because air and energy circulate without obstruction
  • Dome curvature creates higher pressure differentials between windward and leeward sides than flat-roof buildings

Thermal Performance

  • Indoor air temperatures in domed roofs measured 8 K lower than flat-roof equivalents
  • Total heat transfer per surface area was 23% less in dome versus cubic configurations
  • 52% reduction in cooling energy consumption compared to traditional prismatic (rectangular) buildings
  • Annual heating loads 62.6% lower than conventional insulated houses
  • Geodesic dome home consumes 90 kWh/m²/year versus 150 kWh/m²/year for traditional houses (BFI/Oregon Dome data)

Stack Ventilation

The dome’s increased interior height traps hot air at upper levels, leaving occupants in cooler lower zones. Stack ventilation is inherent to the dome form.

CFD Methodology

  • ANSYS FLUENT15 with 3D RANS equations
  • Standard k-epsilon model for incompressible flows
  • Unstructured mesh with 4.6 million elements after grid sensitivity verification
  • Grid sensitivity analysis showed 5.72% average error between medium and fine mesh
  • Mass flux balance maintained below 1% of smallest flux through domain
  • Cross-referenced against prior domed-roof building simulations with good agreement
  • 18 measurement points at 1.2m and 4.2m heights tracked velocity and temperature

Two Ventilation Configurations

  1. Wind-Induced: Upper roof vents positioned to capture pressure differentials between windward and leeward sides
  2. Buoyancy-Induced: Roof vents combined with lower-level windows (windward and leeward sides) enabling stack-driven circulation during low-wind periods

Limitations

Passive roof-vent ventilation alone cannot satisfy thermal requirements during hot summer periods. Supplementary cooling needed. Winter performance is excellent; summer requires hybrid passive-active approach.

Connection to Fuller’s Work

The concave interior enables natural airflow, heating and cooling occurring naturally — validating Fuller’s observations about the DDU (Dymaxion Deployment Unit) “dome effect” first noted in Kansas in 1940. The study establishes domes as viable components of hybrid passive-active cooling systems.

Additional Thermal Efficiency Factors (BFI Data)

  • Decreased surface area reduces material needs
  • Wind flows smoothly around dome reducing heat loss vs. rectangular buildings
  • Interior acts as reflector, concentrating heat and preventing radiant loss
  • No corners or dead air zones — uniform temperature distribution